Channel power measures the total power within a user-defined bandwidth. Channel shift is adjustable with the dialog.
@ -41,27 +43,60 @@ The adjacent channel power measurement measures the power in a channel of user-d
@@ -41,27 +43,60 @@ The adjacent channel power measurement measures the power in a channel of user-d
The 3dB bandwidth measurement measures the bandwidth of a signal, calculated as the frequency difference between where the power falls by 3dB either side of the maximum peak.
The fundamental, harmonics and SFDR are highlighted.
<h3>SNR: Signal to Noise Ratio</h3>
The SNR measurement estimates a signal-to-noise ratio. The fundamental signal is the largest peak (i.e. FFT bin with highest magnitude). The bandwidth of the signal is assumed to be the width of the largest peak, which includes adjacent bins with a monotonically decreasing magnitude. Noise is summed over the full bandwidth (i.e all FFT bins), with the fundamental and user-specified number of harmonics being replaced with the noise median from outside of these regions. The noise median is also subtracted from the signal, before the SNR is calculated.
The SNFR measurement estimates a signal-to-noise-floor ratio. This is similar to the SNR, except that the noise used in the ratio, is only the median noise value calculated from the noise outside of the fundamental and harmonics, summed over the bandwidth of the signal. One way to think of this, is that it is the SNR if all noise outside of the signal's bandwidth was filtered.
@ -81,5 +116,12 @@ SINAD is measured as per SNR, but the result is the ratio of the fundamental to
@@ -81,5 +116,12 @@ SINAD is measured as per SNR, but the result is the ratio of the fundamental to
SFDR is a measurement of the difference in power from the largest peak (the fundamental) to the second largest peak (the strongest spurious signal).
The measurements table has a Spec column that allows entry of user-defined specifications for the Current, Mean, Min and Max values to be checked against.
For example, you might choose to enter >50 in the SFDR row, to check that SFDR is greater than 50dB.
Each time the specification fails to be met, the value in the Fails column is incremented.
Values out of specification are highlighted in red.
The Spec column supports the following operators: <, <=, >, >= and =.