@ -40,27 +40,44 @@ Displays the measurement bandwidth in Hz as determined by the FFT size (4) and t
@@ -40,27 +40,44 @@ Displays the measurement bandwidth in Hz as determined by the FFT size (4) and t
Determines the number of FFTs that are used to measure the average noise power. Using more FFTs can improve accuracy, at the expense of increased measurement time.
<h3>7: Frequency range</h3>
<h3>7: Sweep setting</h3>
Specifies the frequencies to measure the noise figure at. This can be specified as a:
The device setting to sweep should be entered. Predefined values include "centerFrequency" and "gain", but it is possible to
enter any setting supported by the device (that is accessible via the Web API). Not all devices support the "gain" setting.
When "centerFrequency" is set, sweep ranges and values are in MHz. For all other settings, the values are used without any scaling.
Note that some device settings are scaled in the SDRangel GUI compared to the values in the Web API. For example, RTL SDR gain setting of
40.2 in the GUI, is 402 in the Web API.
<h3>8: Sweep range</h3>
Specifies the values of setting (E.g. centerFrequency of gain) to measure the noise figure at. This can be specified as a:
When the sweep setting (7) is "centerFrequency":
* Range - Specify start frequency in MHz, stop frequency in MHz and the number of steps. 100, 200, 5, would measure at 100MHz, 125MHz, 150MHz, 175MHz and 200MHz.
* Step - Specify start frequency in MHz, stop frequency in MHz and the step frequency in MHz. 100, 200, 25, would measure at 100MHz, 125MHz, 150MHz, 175MHz and 200MHz.
* List - Specify a space or comma separated list of frequencies in MHz. "100 125 150 175 200", would measure at 100MHz, 125MHz, 150MHz, 175MHz and 200MHz.
<h3>8: Start/stop noise figure measurement</h3>
For other settings:
* Range - Specify start value, stop value and the number of steps. 100, 200, 5, would measure at 100, 125, 150, 175 and 200.
* Step - Specify start value, stop value and the step. 100, 200, 25, would measure at 100, 125, 150, 175 and 200.
* List - Specify a space or comma separated list of values. "100 125 150 175 200", would measure at 100, 125, 150, 175 and 200.
<h3>9: Start/stop noise figure measurement</h3>
Starts or stops the noise figure measurement. When starting a new measurement, existing results are cleared.
<h3>9: Save results</h3>
<h3>10: Save results</h3>
Saves the results in the table to a .csv file.
<h3>10: Clear results</h3>
<h3>11: Clear results</h3>
Clears the current results from the table and chart.
<h3>11: Open ENR dialog</h3>
<h3>12: Open ENR dialog</h3>
Opens the ENR dialog to allow entering the Excess Noise Ratios (ENRs) for noise source. ENR specifies the difference in noise source power output in dB from when the source is powered off compared to when it is powered on.
This typically varies with frequency, so values should be entered for each calibrated frequency. When a measurement is attempted at a frequency for which a value is not specified, an interpolated value will be used.
@ -68,7 +85,7 @@ You can choose between linear and barycentric rational interpolation, and the di
@@ -68,7 +85,7 @@ You can choose between linear and barycentric rational interpolation, and the di
Opens the noise source control dialog, to allow setting how the plugin turns the power to the noise source off and on. Two control methods are supported: A program or script can be run to turn the power on or off,
or the VISA library (if installed) can be used to send SCPI commands to a programmable power supply or other test equipment. If a VISA library is not found, the VISA and SCPI fields will be disabled.
@ -78,11 +95,11 @@ not too long so that tests over a large number of frequencies take a long time t
@@ -78,11 +95,11 @@ not too long so that tests over a large number of frequencies take a long time t

<h3>13: Results Table</h3>
<h3>14: Results Table</h3>
Displays measurement results.
* Frequency - Frequency of the measurement in MHz.
* Frequency/gain - Frequency of the measurement in MHz, gain or other setting as per (7).
* NF - Calculated noise figure in dB.
* T - Calculated noise temperature in Kelvin with a reference temperature of 290K.
* Y - Measured Y factor in dB (difference in measured power when the noise source is on and off).
Plots the results (NF, T or Y) vs frequency as a line chart.
<h3>15: Open reference data</h3>
<h3>16: Open reference data</h3>
A set of reference data in .csv format can be loaded for comparisons with the measurement results. The first column of the .csv file should contain frequency and the second the noise figure in dB. The first row should contain a header (E.g. "Frequency,NF" allthough the exact text is ignored).
@ -149,6 +166,12 @@ as the total NF is primarily determined by the LNA, if it has a decent amount of
@@ -149,6 +166,12 @@ as the total NF is primarily determined by the LNA, if it has a decent amount of