59 Commits (82de4eceecfa8a040d2fd573ce3bbc8134bd58d4)

Author SHA1 Message Date
f4exb 5174fcdff7 Limit scope time span display to two decimals 10 years ago
f4exb f245dc8206 GLScope: fixed pre-trigger samples initialization when trace size changes 11 years ago
f4exb ca52dbf5b4 Scope GUI: do not apply trigger settings on trace length changed or sample rate changed 11 years ago
f4exb fa754da0f1 Scope GUI: removed unused traceMemoryChanged signal 11 years ago
f4exb 697a6c96fc Scope GUI: update currently displayed trace sample rate when trace history changes. Align all numerical displays on the right 11 years ago
f4exb bbfa4dfd17 Scope GUI: show currently displayed trace sample rate 11 years ago
f4exb 8eb29d9ce0 Scope GUI: block all trigger controls while in trace memory 11 years ago
f4exb dc16def6e3 Scope: block incoming traces (trigger) while in trace memory 11 years ago
f4exb 0d9905c482 GLScope: fixed trace history size bug and set it to 32 positions (2^5) 11 years ago
f4exb f8e6cc6cce GLScope: IQ linear and IQ polar displays 11 years ago
f4exb f891580e78 GLScope: IQ linear and IQ polar displays. Interim state #1: IQ linear 11 years ago
f4exb 9508690863 GLScope: chained multiple triggers 11 years ago
f4exb 8ac778714d GLScope: chained multiple triggers: interim state #3: multiple triggers array in UI 11 years ago
f4exb 2917f015ea GLScope: implemented trigger counts 11 years ago
f4exb ff719059f0 GLScope: chained multiple triggers: interim state #1: implemented array of triggers 11 years ago
f4exb 490bccc5a1 GLScope: trace memory implementation. GLScopeGUI: widgets placement reorganization 11 years ago
f4exb 98125ce93a GLScope: individual settings for channels 1 and 2. Fine and Coarse sliders for Y offsets. 11 years ago
f4exb 1a7610a7e4 GLScope: individual settings for channels 1 and 2. Fine and Coarse sliders for Y offsets. Interim state #1: channel 1 working 11 years ago
f4exb f6b19085fb GLScope: new delta phase displays 11 years ago
f4exb 4ba6f66cac Replaced direct output to console for debug messages with qDebug 11 years ago
f4exb 24ae5ff039 Corrected trigger level display when triggered on phase 12 years ago
f4exb 1e61a5dc29 Display pre-trigger time line on scope 12 years ago
f4exb 4b4a1c57f1 Implemented coarse and fine trigger level sliders 12 years ago
f4exb da9d4d7d52 Display trigger line in linear magnitude mode 12 years ago
f4exb f06c8e1e58 Changed scope trigger level scale and display 12 years ago
f4exb c36104708a Changed scope amplitude offset scale and display 12 years ago
f4exb a93aae8ebf Changed scope amplitude scale and display 12 years ago
f4exb bec9d90bd3 Scope trigger on both edges 12 years ago
f4exb 837ef9f0db Implemented trigger delay 12 years ago
f4exb cafa6b522a Adjusted pre-trigger delay values span control on scope GUI 12 years ago
f4exb 7f98710c19 Implemented variable scope trace length 12 years ago
f4exb 2f195ce6de Corrected scope GUI displays that depend on sample rate 12 years ago
f4exb 833b8c30c7 Rename trigger delay to pre-trigger delay and variables based on trigPre 12 years ago
f4exb de3e3031c2 prepare variable trace length #1 12 years ago
f4exb e0860a0d40 Implemented scope trigger delay 12 years ago
f4exb 3950ec4be9 scope trigger delay preparation #1 12 years ago
f4exb 15a5afad55 Added trace intensity control to scope 12 years ago
f4exb 7ee44dfd27 Corrected channel analyzer decimation and incorrect workarounds 12 years ago
f4exb e0699d9711 Align scope grid on ticks 12 years ago
f4exb 9161e867c9 Added one shot trigger option 12 years ago
f4exb c32f2b72f7 Show trigger line on phase display 12 years ago
f4exb b7a7f898bc Show phase angle in Pi units 12 years ago
f4exb 14d2c87518 Display actual trigger level for log magnitude and phase 12 years ago
f4exb e696e4f8a2 Scope trigger #1 12 years ago
f4exb d67e4e0b82 Prepare scope trigger #2 12 years ago
f4exb 9fa737ec67 Prepare scope trigger #1 12 years ago
f4exb 5f427454a6 Added persistency (serialize/deserialize) of scope display mode (prime, second, both) 12 years ago
f4exb fefbf223e7 Corrected time offset display 12 years ago
f4exb 3d75f2f899 Added options to display scope primary or secondary displays exclusively 12 years ago
f4exb b10cab79ae Display actual units on Y scale amd offset displays 12 years ago