You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
 
 
 
 
 
 
f4exb 62922bd7ba TestSource: set dc and iq buttons state from settings on display settings 9 years ago
..
CMakeLists.txt TestSource: first implementation 9 years ago
readme.md TestSource: Added documentation 9 years ago
testsource.pro Windows build for AirspyHF and TestSource 9 years ago
testsourcegui.cpp TestSource: set dc and iq buttons state from settings on display settings 9 years ago
testsourcegui.h TestSource: fixed some GUI issues 9 years ago
testsourcegui.ui TestSource: implemente DC and IQ bias and corrections 9 years ago
testsourceinput.cpp TestSource: fixed fc infra and supra 9 years ago
testsourceinput.h TestSource: first implementation 9 years ago
testsourceplugin.cpp TestSource: first implementation 9 years ago
testsourceplugin.h TestSource: first implementation 9 years ago
testsourcesettings.cpp TestSource: implemente DC and IQ bias and corrections 9 years ago
testsourcesettings.h TestSource: implemente DC and IQ bias and corrections 9 years ago
testsourcethread.cpp TestSource: implemente DC and IQ bias and corrections 9 years ago
testsourcethread.h TestSource: implemente DC and IQ bias and corrections 9 years ago

readme.md

Test source input plugin

Introduction

This input sample source plugin is an internal continuous wave generator that can be used to carry out test of software internals.

Build

The plugin is present in the core of the software and thus is always present in the list of sources.

Interface

Test source input plugin GUI

1: Common stream parameters

SDR Daemon source input stream GUI

1.1: Frequency

This is the center frequency of reception in kHz.

1.2: Start/Stop

Device start / stop button.

  • Blue triangle icon: device is ready and can be started
  • Green square icon: device is running and can be stopped
  • Magenta (or pink) square icon: an error occured. In the case the device was accidentally disconnected you may click on the icon, plug back in and start again.

1.3: Record

Record baseband I/Q stream toggle button

1.4: Stream sample rate

Baseband I/Q sample rate in kS/s. This is the device to host sample rate (3) divided by the decimation factor (4).

2: Auto correction options

These buttons control the local DSP auto correction options:

  • DC: auto remove DC component
  • IQ: auto make I/Q balance

3: Carrier shift from center frequency

Use this control to set the offset of the carrier from the center frequency of reception.

4: Decimation factor

The I/Q stream from the generator is doensampled by a power of two before being sent to the passband. Possible values are increasing powers of two: 1 (no decimation), 2, 4, 8, 16, 32. This exercises the decimation chain.

5: Baseband center frequency position relative the center frequency

Possible values are:

  • Cen: the decimation operation takes place around the BladeRF Rx center frequency
  • Inf: the decimation operation takes place around the center of the lower half of the BladeRF Rx passband.
  • Sup: the decimation operation takes place around the center of the upper half of the BladeRF Rx passband.

This exercises the decimation chain.

6: Sample rate

This controls the generator sample rate in samples per second.

7: Sample size

This is the sample size in number of bits. It corresponds to the actual sample size used by the devices supported:

  • 8: RTL-SDR, HackRF
  • 12: Airspy, BladeRF, LimeSDR, PlutoSDR, SDRplay
  • 16: Airspy HF+, FCD Pro, FCD Pro+

8: Amplitude coarse control

This slider controls the number of amplitude bits by steps of 100 bits.

9: Number of amplitude bits

This is the signal peak amplitude in number of bits

10: Amplitude fine control

This slider controls the number of amplitude bits by steps of 1 bit.

11: Signal power

This is the signal power in dB relative to the maximum power (full bit range).

12: DC bias

Use this slider to give a DC component in percentage of maximum amplitude.

13: I bias

Use this slider to give an in-phase (I) bias in percentage of maximum amplitude.

14: Q bias

Use this slider to give an quadrature-phase (Q) bias in percentage of maximum amplitude.