@ -865,16 +865,18 @@ void loop()
@@ -865,16 +865,18 @@ void loop()
|
|
|
|
|
sum += deltat; // sum for averaging filter update rate
|
|
|
|
|
sumCount++; |
|
|
|
|
|
|
|
|
|
// Sensors x (y)-axis of the accelerometer is aligned with the -y (x)-axis of the magnetometer;
|
|
|
|
|
// the magnetometer z-axis (+ up) is aligned with z-axis (+ up) of accelerometer and gyro!
|
|
|
|
|
// Sensors x (y)-axis of the accelerometer/gyro is aligned with the y (x)-axis of the magnetometer;
|
|
|
|
|
// the magnetometer z-axis (+ down) is misaligned with z-axis (+ up) of accelerometer and gyro!
|
|
|
|
|
// We have to make some allowance for this orientation mismatch in feeding the output to the quaternion filter.
|
|
|
|
|
// For the BMX-055, we have chosen a magnetic rotation that keeps the sensor forward along the x-axis just like
|
|
|
|
|
// in the MPU9250 sensor. This rotation can be modified to allow any convenient orientation convention.
|
|
|
|
|
// We will assume that +y accel/gyro is North, then x accel/gyro is East. So if we want te quaternions properly aligned
|
|
|
|
|
// we need to feed into the madgwick function Ay, Ax, -Az, Gy, Gx, -Gz, Mx, My, and Mz. But because gravity is by convention
|
|
|
|
|
// positive down, we need to invert the accel data, so we pass -Ay, -Ax, Az, Gy, Gx, -Gz, Mx, My, and Mz into the Madgwick
|
|
|
|
|
// function to get North along the accel +y-axis, East along the accel +x-axis, and Down along the accel -z-axis.
|
|
|
|
|
// This orientation choice can be modified to allow any convenient (non-NED) orientation convention.
|
|
|
|
|
// This is ok by aircraft orientation standards!
|
|
|
|
|
// Pass gyro rate as rad/s
|
|
|
|
|
MadgwickQuaternionUpdate(ax, ay, az, gx*PI/180.0f, gy*PI/180.0f, gz*PI/180.0f, mx, my, mz); |
|
|
|
|
// if(passThru)MahonyQuaternionUpdate(ax, ay, az, gx*PI/180.0f, gy*PI/180.0f, gz*PI/180.0f, mx, my, mz);
|
|
|
|
|
|
|
|
|
|
MadgwickQuaternionUpdate(-ay, -ax, az, gy*PI/180.0f, gx*PI/180.0f, -gz*PI/180.0f, mx, my, mz); |
|
|
|
|
// if(passThru)MahonyQuaternionUpdate(-ay, -ax, az, gy*PI/180.0f, gx*PI/180.0f, -gz*PI/180.0f, mx, my, mz);
|
|
|
|
|
// Serial print and/or display at 0.5 s rate independent of data rates
|
|
|
|
|
delt_t = millis() - count; |
|
|
|
|
if (delt_t > 500) { // update LCD once per half-second independent of read rate
|
|
|
|
|